Materials · PEEK

PEEK is decided
by the mold temperature.

PEEK is the structural thermoplastic medical and high-temperature programs reach for first. It is also the one that punishes a cold tool most quietly: the part fills, looks right and measures right on the day, and then keeps changing. Here is what governs a PEEK micro part, and where the numbers on a certificate stop applying.

Overview

Crystallinity is set in the tool, not the pellet

PEEK is semi-crystalline, and how much of it crystallises depends on how long the melt spends above its glass transition while it cools. A mold held well above that transition gives the chains time to order; a cold mold freezes a skin that is largely amorphous. The amorphous skin is weaker in chemical resistance, lower in stiffness and not finished moving — it can crystallise later, in service or in an autoclave, and shrink as it does. Small parts have the least thermal mass to hold heat, so they sit on the wrong side of this more easily than large ones.

Unfilled shrinks evenly. Filled does not.

Unfilled PEEK shrinks about the same in every direction, and more than an amorphous resin does. Add 30% glass or carbon fibre and the fibres line up with the flow and refuse to shrink along it, so the part shrinks several times more across the flow than along it. On a micro part that is not a correction factor to average out — it is two different materials depending on which way a dimension runs relative to the gate. Gate position decides which of your dimensions gets the easy direction.

Thin walls freeze before they pack

PEEK is viscous and it freezes fast against steel, so a thin section far from the gate can solidify before packing pressure reaches it. The gate itself is usually the thinnest section in the system and freezes first, which ends packing for the whole part. That is why gate size and location are settled in the tool design for PEEK rather than tuned at the press, and why a gate-seal study belongs in the first sampling run.

Filled grades wear the steel

Glass and carbon fibre at melt temperature are abrasive. Gates, runner corners and any sharp detail they flow past wear first, and at micro scale a gate that has opened up by a few microns changes when it freezes. Filled PEEK is a steel-selection decision made before the tool is cut, not a maintenance note afterwards.

What a medical-grade PEEK certificate means

Implant and medical grades of PEEK are sold with testing behind them — biocompatibility to ISO 10993, USP Class VI, implant-grade specifications. That testing is on the grade as supplied. It does not transfer to a molded part on its own: processing, colourants, mold release and cleaning all sit between the pellet and the device, and qualifying the finished part for patient contact is the device owner’s job under their own quality system. What a molder can do is keep the grade traceable and the process documented, so the qualification has something to stand on.

The shrink budget at micro scale

The shop’s molded-part figure is ±10 µm. On a 2 mm feature, this is how much of that band each grade’s own shrink range takes before the machine, the tool or the gauge have done anything — the same arithmetic the shrinkage calculator runs, on the Lab’s starting-point table for the family.

2.000 mm ± 0.010 mm
GradeDirectionShrink rangeTolerance takenReading
PEEK (unfilled)Any direction1.1–1.3%20%Room to work
PEEK, 30% glassAlong flow0.2–0.4%20%Room to work
PEEK, 30% glassAcross flow0.9–1.3%40%Room to work

A family range is wider than a stable process window on one grade, so these are the worst-case budget, not a prediction. Replace the range with your grade’s datasheet figure in the calculator and the answer tightens.

Run your own dimension in the shrinkage calculator.

Grades and properties

PEEK

High-temp · biocompatible

Polyether ether ketone is the gold-standard structural thermoplastic for implantable and sterilizable devices. It retains strength at continuous-use temperatures above 250 °C and resists aggressive chemical sterilants.

Typical grades
Victrex 450G, 150CA30
Thermal
Tg 143 °C · Tm 343 °C

Properties

  • Continuous-use temp to 260 °C
  • Tensile strength 100 MPa unfilled
  • Chemical resistance to most sterilants
  • Radiolucent — MRI/X-ray transparent
  • Low moisture absorption < 0.5%

Grades are supplied to

  • ISO 10993 biocompatibility
  • USP Class VI
  • ASTM F2026 implant grade

These are standards the material grade is tested or supplied to by its manufacturer. They describe the resin or the bar stock, not a finished part — qualifying a part for patient contact is the device owner’s decision, made under their own quality system.

Have a part in PEEK? Send the drawing with the grade and the dimensions that matter, or talk it through with Marve first.